| Compliance List |
5 CSR 25-500.032 Organization and Administration
Not Observed
|
5 CSR 25-500.042 Licensing Process
Not Observed
|
5 CSR 25-500.052 Annual Requirements
Not Observed
|
5 CSR 25-500.082 Physical Requirements of Group Day Care Homes and Day Care Centers
Violation
| | Provider Comments |
Violation The requirements for protective outlet covers or twist-lock outlets were not met as evidenced by electrical outlets were not covered in that surge protector in the new infant space did not have outlet covers. Licensing Rule Reference 5 CSR 25-500.082 Physical Requirements of Group Day Care Homes and Day Care Centers (1) (G) states: Protective outlet covers or twist-lock outlets shall be used in areas accessible to the children. Correction Required The facility shall use outlet covers or twist-lock outlets as required.
Correction Verification Corrected on Site
Compliance Date 7/28/2026
|
|
Violation Hazardous items as follows were accessible to children: air fresheners. The item(s) was/were located in an unlocked cabinet below the sinks in the new I/T spaces. Licensing Rule Reference 5 CSR 25-500.082 Physical Requirements of Group Day Care Homes and Day Care Centers (1) (I) states: All flammable liquids, matches, cleaning supplies, poisonous materials, medicines, alcoholic beverages, hazardous personal care items or other hazardous items shall be inaccessible to children. Correction Required Hazardous items shall be inaccessible to children.
Correction Verification Corrected on Site
Compliance Date 7/28/2026
|
|
Violation The walls located in the boys bathroom was/were not finished with material which can be cleaned easily as evidenced by drywall exposed above the light switch plate . Licensing Rule Reference 5 CSR 25-500.082 Physical Requirements of Group Day Care Homes and Day Care Centers (2) (A) 6. states: Walls, ceilings and floors shall be finished with material which can be cleaned easily and shall be free of splinters, cracks and chipping paint. Floor covering shall be in good condition. Lead-free paint shall be used for all painted surfaces. Correction Required Walls, ceilings, and floors shall be made of approved materials, easily cleaned and in good condition.
Correction Verification Submit Documentation
Compliance Date
|
|
|
5 CSR 25-500.087 Fire Safety
Not Observed
|
5 CSR 25-500.090 Disaster and Emergency Preparedness
Violation
| | Provider Comments |
Violation The facility's disaster and emergency plan was not available in each room used for childcare as evidenced by not available in the new I/T spaces. Licensing Rule Reference 5 CSR 25-500.090 Disaster and Emergency Preparedness (2) (A) states: At all times, a copy of the facility's disaster and emergency plan is readily available in the office area and in each room used for care of children; Correction Required The facilities disaster and emergency plan must be available in required locations.
Correction Verification Corrected on Site
Compliance Date 7/28/2026
|
|
|
5 CSR 25-500.092 Furniture, Equipment and Materials
Violation
| | Provider Comments |
Violation Sleeping equipment was not arranged to provide required spacing as evidenced by the aisle on the long side of the napping equipment was too narrow - the space measured less than 2' (2 cribs). Licensing Rule Reference 5 CSR 25-500.092 Furniture, Equipment and Materials (1) (B) 1. D. states: Sleeping equipment shall be arranged to provide at least a two foot (2') aisle on one (1) long side of the equipment. Correction Required Caregivers shall provide a two foot (2') aisle on one long side of the napping equipment.
Correction Verification Corrected on Site
Compliance Date 7/28/2026
|
|
|
5 CSR 25-500.102 Personnel
Compliance
|
5 CSR 25-500.112 Staff/Child Ratios
Compliance
|
5 CSR 25-500.122 Medical Examination Reports
Not Observed
|
5 CSR 25-500.132 Admission Policies and Procedures
Not Observed
|
5 CSR 25-500.142 Nighttime Care
Not Observed
|
5 CSR 25-500.162 Overlap Care of Children
Not Observed
|
5 CSR 25-500.172 Emergency School Closings
Not Observed
|
5 CSR 25-500.182 Child Care Program
Not Observed
|
5 CSR 25-500.192 Health Care
Not Observed
|
5 CSR 25-500.202 Nutrition and Food Service
Not Observed
|
5 CSR 25-500.212 Transportation and Field Trips
Not Observed
|
5 CSR 25-500.222 Records and Reports
Not Observed
|
5 CSR 25-600.020 General Requirements
Not Observed
|
5 CSR 25-600.040 Background Screening Findings
Not Observed
|
RSMo 210.115. Reports of abuse, neglect, and under age eighteen deaths — persons required to report — supervisors and administrators not to impede reporting — deaths required to be reported to the division or child fatality review panel, when — report made to another state, when. —
Not Observed
|
RSMo 210.211. License required - exceptions - written notice of licensure status, when.
Not Observed
|